Evaluation of Combined Ultrasonography and Cone Beam Computed Tomography for Clinical Imaging: A Negative Results Study
Dennis Flanagan, Anna Tarakonova, Anshika Pandey, Patrick Kumavor, Carmen Lo, Mohammad Mundiwala
- 1 Jacksonville University
- 2 U Conn
責任著者・Dennis Flanagan, Jacksonville University
要旨
The combination of ultrasonography (US) and cone beam computed tomography (CBCT) has been proposed as a multimodal imaging strategy capable of uniting real-time soft-tissue assessment with high-resolution three-dimensional visualization of osseous structures. This study critically evaluated whether such integration provides measurable diagnostic or workflow advantages in mandibular imaging. Despite strong theoretical justification, the combined use of US and CBCT failed to demonstrate clinically meaningful improvements in diagnostic accuracy, confidence, or efficiency when compared with CBCT alone. Fundamental physical mismatches, hardware incompatibilities, geometric constraints, and operator-dependent variability limited the anticipated synergistic benefits. These negative findings underscore the importance of reporting unsuccessful integration attempts to guide future research and prevent premature clinical adoption of technically incompatible imaging paradigms.
この論文を引用する
Dennis Flanagan, Anna Tarakonova, Anshika Pandey, Patrick Kumavor, Carmen Lo, Mohammad Mundiwala (2026). Evaluation of Combined Ultrasonography and Cone Beam Computed Tomography for Clinical Imaging: A Negative Results Study. Journal of Biotechnology and Biomedical Science 3(2):28–32. https://doi.org/10.14302/issn.2576-6694.jbbs-26-5964.